2D numerical model of downward push pull ventilation for protecting workers against airborne infection

Authors

DOI:

https://doi.org/10.56294/saludcyt2022151

Keywords:

Covid-19, Droplets, Push-pull Ventilation, Speed Ratio

Abstract

Industrial clusters contributed significantly to the spread of Covid-19 worldwide, including in Indonesia. One of the causes is that maintaining a minimum distance of 1 to 2 meters between workers is often challenging due to the plant layout and work system design limitations. Therefore, an intervention to the workstation is needed to protect industrial workers from potential exposure to Covid-19 and other airborne infections. One technology that has a high potential to be applied to solve this problem is the air curtain/personalized ventilation. This research analyzes the effectiveness of downward push-pull air curtain in protecting workers from inhaling the infected microdroplet. The extent to which the downward push-pull ventilation can withstand the burst of microdroplets was studied by varying the air speed ratios of the air curtain. A 2D simulation was carried out with Salome, OpenFOAM, and ParaView softwares. Two scenarios were tested, i.e., the distance between the person who is coughing is 0,5 and 1 meter from the air curtain. For the distance of 0,5 meter, the results showed that the optimum velocity ratio between the pushed and pulled air was 0,17 with a droplet penetration percentage of 8,98 %. While for 1 m, the optimum velocity ratio was 0,25 with a droplet penetration percentage of 5,67 %

References

1. Saidan MN, Shbool MA, Arabeyyat OS, Al-Shihabi ST, Abdallat YA, Barghash MA, Saidan H. Estimation of the probable outbreak size of novel coronavirus (COVID-19) in social gathering events and industrial activities. Int J Infect Dis. 2020;98:321-7. doi: 10.1016/j.ijid.2020.06.105.

2. Lu J, Gu J, Gu J, Li K, Xu C, Su W, Lai Z, Zhou D, Yu C, Xu B, Yang Z. COVID-19 outbreak associated with air conditioning in a restaurant in Guangzhou, China, 2020. Emerg Infect Dis. 2020;26(7):1628-31. doi: 10.3201/eid2607.200764.

3. Li Y, Leung GM, Tang JW, et al. Role of ventilation in airborne transmission of infectious agents in the built environment: a multidisciplinary systematic review. Indoor Air. 2007;17:2-18. doi: 10.1111/j.1600-0668.2006.00445.x.

4. Jiang Y, Zhao B, Li X, et al. Investigating a safe ventilation rate for the prevention of indoor SARS transmission: an attempt based on a simulation approach. Build Simul. 2009;2:218-89. doi: 10.1007/s12273-009-9325-7.

5. Nielsen PV. Control of airborne infectious diseases in ventilated spaces. J R Soc Interface. 2009;6:218-89. doi: 10.1098/rsif.2009.0228.focus.

6. Cermak R, Melikov AK. Protection of occupants from exhaled infectious agents and floor material emissions in rooms with personalized and underfloor ventilation. HVAC R Res. 2007;13:23-38. doi: 10.1080/10789669.2007.10390942.

7. Bolashikov ZD, Melikov AK. Methods for air cleaning and protection of building occupants from airborne pathogens. Build Environ. 2009;44:1378-85. doi: 10.1016/j.buildenv.2008.09.001.

8. Xu C, Liu L. Personalized ventilation: one possible solution for airborne infection control in highly occupied spaces. Indoor Build Environ. 2018;27:873-6. doi: 10.1177/1420326X18777383.

9. Gupta JK, Lin CH, Chen Q. Flow dynamics and characterization of a cough. Indoor Air. 2009;19(6):517-25. doi: 10.1111/j.1600-0668.2009.00619.x.

10. Xie X, Li Y, Sun H, Liu L. Exhaled droplets due to talking and coughing. J R Soc Interface. 2009;6. doi: 10.1098/rsif.2009.0388.focus.

11. Huang RF, Lin SY, Jan SY, et al. Aerodynamic characteristics and design guidelines of push-pull ventilation systems. Ann Occup Hyg. 2005;49:491-15. doi: 10.1080/15459620601155749.

12. Chern MJ, Ma CH. Numerical investigation and recommendations for push-pull ventilation systems. J Occup Environ Hyg. 2007;4:184-97.

Downloads

Published

2022-12-31

How to Cite

1.
Sari Dewi R, Moballa B, Maryani A, Tamimah N, Hafidz Bramansyah D, Wahyudin M. 2D numerical model of downward push pull ventilation for protecting workers against airborne infection. Salud, Ciencia y Tecnología [Internet]. 2022 Dec. 31 [cited 2024 Nov. 21];2:151. Available from: https://sct.ageditor.ar/index.php/sct/article/view/88